DSC Alarm panels
Power Series PC1616/PC1832/PC1864
MAXSYS PC4020
Applications supported
SIA alarm transmission
Remote upload/download via WebWay ATS and WebWay Remote Manager
Power series PC1616/PC1832/PC1864 installation using the WebWay Dial Capture Module (DCM)
Connect the WebWay PSTN panel interface A and to the A and B terminals of the DSC control panel. Connect the
WebWay PWR + and - to the Aux + and Aux - of the DSC control panel.
Maxsys PC4020 series installation using the WebWay dial capture
Connect the WebWay PSTN panel interface A and B (location 6 in figure 1 (or to the DC option board - terminals A and B)
to the A and B terminals of the DSC control panel. Connect the WebWay PWR + and - to the Aux + and Aux - of the DSC
control panel.
On the Panel PC1616/PC1832/PC1864
Go to section 301: Enter telephone number <01234 567890> (any valid phone number is acceptable)
Go to section 310: Enter account number <______>
Go to section 350: Enter communicator format to SIA <04>
Go to section 380: Ensure option 1 is enabled to <1________>
Go to section 381: Ensure options 5 & 6 are enabled - the rest clear <____56__>
Go to section 382: All must be clear <_________>
Go to section 401: Option 1 must be set - the rest clear<1________>
Go to section 403: Enter DLS access code <______>
Go to section 404: Enter DLS panel identification code <______>
Go to section 406: Set number of rings to <002>